external source tank on the outside ofthe machine does not store recovered refrigerant. All R-134a refrigerant source tanks have internal check valve that wall only allow the flow of-new refrigerant from the source Lank. It is not possible to fill or refill R-134a source tanks. The Internal Storage Vessel (ISV) will maintain a constant 12-15 lbs.

Robinair high tank pressure. Things To Know About Robinair high tank pressure.

Robinair 34788ni = High Tank Pressure Tool & Equipment Posted on Forum 7/15/2017 5 Reply Hey Guys, a good start on Saturday morning! brand new 34788ni used once before this morning. Had three AC jobs scheduled for the day, recovered one problem, hooked up to the second one and started recovering and walked away a little bit.Refrigerant Tank. 30 lb. tank, 1/4" fittings (25150, 25175, 25200B, 34234, 34300-2K, 34800 series). Documents; Nitrogen SDS for empty refrigerant tanks ... Invent with Robinair; …High-Side Manifold Gauge – connects to vehicle A/C system and shows system’s high-side pressure. Low-Side Manifold Gauge – connects to vehicle A/C system and shows system’s low-side pressure. High-Side Flow Indicator – an illuminated red light indicates high-side flow from the vehicle A/C system through the unit. Low-Side Flow ...May 2, 2012 · the tank is empty,the machine will not come out of clearing in any mode.i connected a service gauge on the manifold block when entering recovery it pulls down to 20 psi and will go no lower,is the compressor failing,shouldnt it pull to 0 psi.if i close the tank valves with the unit recovering it never hits high pressure.

Septic tanks are an essential part of any home’s plumbing system, and when it comes time to install one, you may be wondering what the cost will be. Septic tanks come in two main types: concrete and plastic. Concrete tanks are more expensiv...13169 Robinair 13169 Robinair Spin-On Filter Maintenance Kit With 34430 Recycling Filter Drier. Contains one quick change filter-drier to be used on both R-12 and R-134a stations, and one 16 ounce bottle of our Premium High Vacuum Pump Oil. For early models using 34430 Filter-Drier (17700A, 34700, 34300-2K). See your instruction manual if you ...

• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalRobinair A/C refrigeration Recycling Machine Filter model. 12/8/2016. I have a 1999 robinair a/c machine its been in the back room. 5/9/2016. I have a 34788 the service tank was empty over the winter, 5/8/2016. MY ROBINAIR MODEL #34788 IS STUCK IN A GH PRESSURE RESET.

Wear safety goggles when working with refrigerant. All hoses may contain liquid refrigerant under pressure. Disconnect hoses using extreme caution. Read and follow all warnings at the beginning of this manual before operating the unit. R-134a High-side. Service Hoses Hose. Storage Fitting. R-134a Low-side Hose. Storage Fitting. Source. Tank ... Bosch Automotive Service Solutions, Inc. 28635 Mound Road Warren, MI 48092 USApressure of Recovery Tank cylinder. 5. m Warning: DO NOT: Exceed the working pres- sure of each cylinder. Recovery cylinders are designed for different pressures. Your 25175B is not supplied with a recovery tank, it requires the use of tanks with a minimum of 350 psi working pressure and ROBINAIR strongly recommends the use of 400 psi tanks. down when the storage tank reaches 80% capacity if the float cable is used correctly. Use only Robinair tank p/n 17990 with this machine. Shut-off Switch This unit has an internal, high-pressure, shut-off switch. If system pressure rises above 435 psi, the unit shuts off. The shut-off switch automatically resets itself after80211VCI refrigerant capacity database activation instructions. R-1234yf vs R-134a Robinair machine comparison (2001_541) Robinair 134a A/C Machine Comparison Chart (Document # 16-74) SDS high vacuum …

Note: Use only high vacuum pump oil such as Robinair’s Premium High Vacuum Pump Oil. Other oils will prevent pull-down to a deep vacuum. 4. Verify the gas ballast knob is tightly closed. 5. Verify the oil is at the correct level. For maximum pump operation, the oil must be even with the OIL LEVEL line on the sight glass when the pump is running.

You’re passing up on R-1234YF revenue. Invest in a new machine, new leak detector and a new oil inject syringe to grow your business

ROBINAIR.COM 800.533.6127 Recover, Recycle, Recharge Machine for Heavy Duty R-134a A/C Systems ... Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating voltage. ... use only type-approved refillable containers that have pressure relief valves. HOSES CAN CONTAIN LIQUID REFRIGERANT …Pressure / Temperature Chart Door Screw Door Screw System Oil Drain Valve Low Side Gauge High Side Gauge High Side Valve Liquid/Vapor Indicator Display Main Power Switch Air Purge Valve Keypad Low Side Valve Tank Pressure Gauge Setup Instructions INST0919 Unit Circuit Breaker (17800B only) System Oil Indicator Oil-less Compressor Protector Tank ...PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Do not overfill storage vessels, because ... Robinair strongly recommends that a . ... This unit has an internal, high-pressure, shut-off switch. If system pressure rises above 550 psi, the unit shuts off.All new proprietary "Oil-less" compressor and 1/2 hp motor. Field serviceable compressor. Multi-refrigerant capable with Self-Clearing feature, which prevents cross-contamination. One 60" hose included. 1/4" MFL fittings. Optional Float Cable provides automatic shut off when tanks are 80% full. Power Source - 115V 60 Hz.High Side Port Low Side Port Lockout Door Blue Liquid Hose Red Vapor Hose Yellow Air Purge Hose Tank Liquid Valve Tank Vapor Valve Air Purge Fitting 50 lb. (23 kg) Unit Tank Scale Assembly INST0917 Hermetic Compressor Filter-Drier Oil-less Compressor Setup Instructions Vacuum Pump HI-P Access Port

Robinair 34788ni = high tank pressure Posted to Tool & Equipment Forum on 7/15/2017 5 Replies Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and walked away for a bit. come back itsWear safety goggles when working with refrigerant. All hoses may contain liquid refrigerant under pressure. Disconnect hoses using extreme caution. Read and follow all warnings at the beginning of this manual before operating the unit. R-134a High-side. Service Hoses Hose. Storage Fitting. R-134a Low-side Hose. Storage Fitting. Source. Tank ... conditions (10°C to 50°C) keeps pressures under reasonable limits. DO NOT USE THIS MACHINE OUTDOORS DURING RAIN OR HIGH HUMIDITY . Protect the machine from …Bosch Automotive Service Solutions, Inc. 28635 Mound Road Warren, MI 48092 USAFor Robinair service center use only. Menu Choice: Calibration Check Use to verify internal scale calibration. Refer to instructions in Maintenance section under Scale Calibration Check. Menu Choice: Adjust Tank Fill Lvl During the tank refill process, the unit stops refilling when it reaches the pre-set amount of refrigerant in the internal

Robinair 34788ni high tank pressure Robinair 34788ni = high tank pressure Posted to Tool & Equipment Forum on 7/15/2017 5 Replies Hey guys, good start to a saturday morning! brand new 34788ni used once before this morning. had 3 ac jobs scheduled for the day, recovered one no problem, hooked to the second one and started recover and …

Premier R-134A Refrigerant Recovery, Recycling, and Recharging MachineRobinair introduces its next innovation, the 34788NI, featuring an industry leading 98....Sep 26, 2014 · Traffic on JustAnswer rose 14 percent...and had nearly 400,000 page views in 30 days...inquiries related to stress, high blood pressure, drinking and heart pain jumped 33 percent. Tory Johnson, GMA Workplace Contributor, discusses work-from-home jobs, such as JustAnswer in which verified Experts answer people’s questions. RA19895 Robinair Air Purge Solenoid Assembly 120V. ... 19740 Robinair Source Tank Filter For 134A 115642 Robinair 12oz. Oil Drain - Oil Injector Bottle 569103 Robinair Door Latch Kit Sidewinder Cabinet 522975 Robinair 116" High Side Enviro-Guard Hose Coupler Set R134A Price $65.20 . Add : Price $7.99 . Add : Price $26.70 .Robinair 34788ni = High Tank Pressure Tool & Equipment Posted on Forum 7/15/2017 5 Reply Hey Guys, a good start on Saturday morning! brand new 34788ni used once before this morning. Had three AC jobs scheduled for the day, recovered one problem, hooked up to the second one and started recovering and walked away a little bit.Robinair 34788ni = High Tank Pressure Tool & Equipment Posted on Forum 7/15/2017 5 Reply Hey Guys, a good start on Saturday morning! brand new 34788ni used once before this morning. Had three AC jobs scheduled for the day, recovered one problem, hooked up to the second one and started recovering and walked away a little bit.Robinair A/C Machine replacement parts including High / Low Side Couplers, Hoses, Filters, Tank Fill Adapters, Oil Bottles, Solenoids, Dust Covers and more. Products search. Parts & Breakdowns. A/C Machines. Robinair; Brake Lathes. Accu-turn; ... Robinair J-45096 Transflow Parts.NOTE: If using a refillable source tank, connect the tank adapter to the vapor valve. R-134a Tank Adapter 2. Connect the service coupler of the low-side hose (blue) to the refrigerant source tank. 3. Open the valve on the source tank, and place the tank upside down in the source tank compartment. PAGE 13

• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or national

YES button is pressed. Verify the high- and low-side hoses are connected and the coupler valves are open. Press STOP / NO to exit at this point. To ensure complete recovery of refrigerant, the unit will automatically wait 5 minutes and monitor for a rise in pressure above 0 in. Hg. Note: The high- and low-side lights on the control

Robinair lock out high pressure - iATN. Robinair lock out high pressure. Posted to the Waveform Library on 2/23/2020. Screen shots of what the machine shows when there is high pressure in tank and how to fix it.• Over pressure valves. • A maximum pressure switch stops the compressor when excessive pressure is sensed. WARNING: Tampering with these protective devices could result in serious injury . Refrigerant Tank Test Official records and recurring tests necessary for pressurized instruments are governed by laws and/or nationalPRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. Do not overfill the internal storage vessel, ... The unit includes a 1.5 cfm (42 l/m) Robinair high vacuum pump for fast, thorough evacuation. The compressor pulls the A/C system to 0 psig ... and high-side pressure. power Cord. 543175 Rev. F, February 15, 2010 3 Introduction Keypad Functionscombustible at elevated pressures. These mixtures, if ignited, may cause injury or property damage. TO PREVENT CROSS-CONTAMINATION, USE THIS UNIT WITH R-134a REFRIGERANT ONLY. The unit is designed to recover, recycle, and recharge only R-134a refrigerant. Do not attempt to adapt the unit for another refrigerant.MY ROBINAIR MODEL #34788 IS STUCK IN A HIGH PRESSURE RESET MODE AND WILL NOT WORK. WHAT CAN I DO? - Answered by a verified HVAC TechnicianSingle ROBINAIR 539993 HARNESS,GROUND RA20008-1 Robinair Ferrule and Nut 1/8 Inch( 1 Piece) ROBINAIR 523149 OIL BOTTLE MEDAL CAP (1) ROBINAIR 120225 TUBE 1/4 OD X 0.040 WALL RA20005 Robinair 3/8 High Pressure Tube 18 Inches Long ROBINAIR 539654 TEE, MALE BRANCH 1/8 NPTF ROBINAIR 13203 ONE QUART …i have a robinair a/c machine 34788-h that will not work anymore keeps sending error message pressure too high . DO YOU KNOW WHAT PART IS MOST …combustible at elevated pressures. These mixtures, if ignited, may cause injury or property damage. TO PREVENT CROSS-CONTAMINATION, USE THIS UNIT WITH R-134a REFRIGERANT ONLY. The unit is designed to recover, recycle, and recharge only R-134a refrigerant. Do not attempt to adapt the unit for another refrigerant.RA19104 Robinair High Pressure Cutout 435 PSI High Pressure Cutout 17650 / 17655 A normally closed sensor that opens, stopping the recovery process when the compressor discharge pressure reaches 435 psi. SPDT Contact arrangement. 1/4 spade termination. Robinair does not warrant any "RA" repair item not installed by an Authorized Service …Robinair cannot know, evaluate, and advise you as to all possible hazards. You must verify that conditions and procedures do not jeopardize your personal safety. Explanation of Safety Decals Used on the 34788NI/34788NI-H. Carefully read the instructions. Do not use in open air in case of rain or high hu-midity. Wear gloves. Wear protection goggles.View online (41 pages) or download PDF (3 MB) Robinair 34788NI-H, 34788NI, 34788NI-230 Operating manual • 34788NI-H, 34788NI, ... HIGH TANK PRESSURE. INLET PRESSURE IS TOO . HIGH FOR VACUUM. 68 kg (150 lb) or more refrigerant has been recovered since last filter change.Robinair cannot know, evaluate, or advise as to all possible hazards. The user must verify that conditions and procedures do not jeopardize personal safety. Explanation of Safety Decals Used on the Machine Carefully read the instructions. Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating ...

Refrigerant Tank. 30 lb. tank, 1/4" fittings (25150, 25175, 25200B, 34234, 34300-2K, 34800 series). Documents; Nitrogen SDS for empty refrigerant tanks. Contact Us; Catalogs; Media Downloads; Invent with Robinair; Service Center Application Form; Customer Service / Tech Support 1-800-533-6127. [email protected] . Bosch Automotive Service ...ROBINAIR.COM 800.533.6127 Recover, Recycle, Recharge Machine for R-134a A/C Systems ... Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating voltage. ... use only type-approved refillable containers that have pressure relief valves. HOSES CAN CONTAIN LIQUID REFRIGERANT UNDER …RA19427 Robinair High Pressure Switch High Pressure Switch If pressure inside the unit exceeds 435psi, the switch opens, stopping all functions of unit. NOTE: Switch opens at 435psi +/- 10psi and resets at 320psi +/- 20psi. Robinair does not warrant any "RA" repair item not installed by an Authorized Service Center.Instagram:https://instagram. facebook marketplace ardmore okandrew wighinschris harris jr collegemezozoic down when the storage tank reaches 80% capacity if the float cable is used correctly. Use only Robinair tank p/n 17990 with this machine. Shut-off Switch This unit has an internal, high-pressure, shut-off switch. If system pressure rises above 435 psi, the unit shuts off. The shut-off switch automatically resets itself afterRefrigerant Tank. 30 lb. tank, 1/4" fittings (25150, 25175, 25200B, 34234, 34300-2K, 34800 series). Documents; Nitrogen SDS for empty refrigerant tanks ... Invent with Robinair; … wsu athletic performance centerpelican bandit 100 nxt kayak review Robinair cannot know, evaluate, and advise you as to all possible hazards. You must verify that conditions and procedures do not jeopardize your personal safety. Explanation of Safety Decals Used on the 34788NI/34788NI-H. Carefully read the instructions. Do not use in open air in case of rain or high hu-midity. Wear gloves. Wear protection goggles.Set the beeper tone to high (Beeper 1), low (Beeper 2) or none (Mute). Service Menu Robinair service center use only. Hose Flush Flushes any residual oil from the unit for service of vehicles with different oils. Display Tank Info Displays internal storage vessel (ISV) pressure and temperature. Use to check the ISV for excessive pressure. Stop ... lucro significado All new proprietary "Oil-less" compressor and 1/2 hp motor. Field serviceable compressor. Multi-refrigerant capable with Self-Clearing feature, which prevents cross-contamination. One 60" hose included. 1/4" MFL fittings. Optional Float Cable provides automatic shut off when tanks are 80% full. Power Source - 115V 60 Hz.The 34288NI-230 combines simple operation with superior accuracy. It recovers, recycles, evacuates and recharges R-134A mobile A/C systems quickly and accurately. The product is designed to meet and outperform the most current SAE J-2788 standards for accuracy and efficiency, recovering more than 95% of the refrigerant in a vehicle's A/C system ...